Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chemosphere ; 300: 134473, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35367490

RESUMO

Laboratories use different strategies to sample and extract atmospheric particulate matter (PM), some of which can be very complicated. Due to the absence of a standard protocol, it is difficult to compare the results of PM toxicity assessment across different laboratories. Here, we proposed a novel PM sampling and cell exposure strategy based on agar membrane. The agar membrane, prepared by a simple freeze-drying method, has a relatively flat surface and porous interior. We demonstrated that the agar membrane was a reliable substitute material for PM sampling. Then the PM on the agar membranes was directly extracted with the culture medium by vortex method, and the PM on the polytetrafluoroethylene (PTFE) filters was extracted with water by the traditional ultrasonic method for comparison. The extraction efficiency was evaluated and in vitro cytotoxicity assays were carried out to investigate the toxic effects of PM extracted with two strategies on macrophage cells. The results showed that the PM extracted from agar membranes induced higher cytotoxicity and more differentially expressed proteins. Overall, the novel PM sampling-cell exposure strategy based on the agar membrane is easy to operate, biocompatible and comparable, and has low disturbance, could be an alternative sampling and extraction method for PM toxicity assessment.


Assuntos
Poluentes Atmosféricos , Material Particulado , Ágar , Poluentes Atmosféricos/análise , Material Particulado/análise , Água
2.
Ecotoxicol Environ Saf ; 191: 110223, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-31991395

RESUMO

Differences of cytotoxicity associated with exposure to different extracts of atmospheric particulate matters (PMs) are still not well characterized by in vitro toxicoproteomics. In this study, in vitro cytotoxicity assays and toxicoproteomic analyses were carried out to investigate toxic effects of PM collected using polytetrafluoroethylene (PTFE) filters extracted with acetone for PM2.1 and water for PM2.1 and PM10 on A549 human lung epithelial cells. The cytotoxicity assays based on cell viability, cell apoptosis and reactive oxygen species generation indicated that PM2.1 extracted with acetone had the highest toxicity. iTRAQ labeling and LC-MS/MS analyses indicated that the number of differentially expressed proteins in A549 cells affected by PM2.1 extracted with acetone was noticeably higher than that of the other two groups. Hierarchical cluster analyses showed that the influences of the extracts of PM2.1 and PM10 using water on the proteome of A549 cells were similar, whereas significantly different from the effect of PM2.1 extracted with acetone. Pathways analyses indicated that PM2.1 extracted with acetone influenced the expression of proteins involved in 14 pathways including glycolysis/gluconeogenesis, pentose phosphate pathway, proteasome, etc. PM2.1 extracted with water affected the expression of proteins involved in 3 pathways including non-homologous end-joining, ribosome and endocytosis. However, PM10 extracted with water affected the expression of proteins involved in only spliceosome pathway. The extracts of PM using different extractants to detach PM from PTFE filters influenced the cytotoxic effects of PM and the proteome of A549 cells. Therefore, extractants should be assessed carefully before the investigations on cytotoxicity to improve the compatibility of experimental results among research teams.


Assuntos
Poluentes Atmosféricos/toxicidade , Material Particulado/toxicidade , Células A549 , Acetona , Apoptose , Atmosfera/química , Sobrevivência Celular/efeitos dos fármacos , Citotoxinas/toxicidade , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/metabolismo , Humanos , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Politetrafluoretileno , Proteoma/metabolismo , Proteômica/métodos , Água
3.
Anal Chem ; 92(1): 1058-1067, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-31826605

RESUMO

A facile solvothermal method was developed for synthesis of magnetic nickel-based iron oxide nanocomposites (MNFOs) with different ratios of Ni2+ to Fe3+ for different reaction time. Two factors including dosage of Ni source and length of reaction were investigated for influence on the morphology and composition of MNFOs, as well as their distinct selectivity for different phosphopeptides. After thorough characterization, the possible formation mechanism of MNFOs was proposed. Very interestingly, MNFOs with Ni2+/Fe3+ ratios of 4:5 prepared for 8 h (MNFO-S) and for 24 h (MNFO-L) can selectively capture global- and monophosphopeptides at the fmol level with excellent enrichment performance. These two affinity probes have been exploited to isolate and enrich the phosphopeptides from human normal hepatic cells HL 7702 after exposure to atmospheric fine particulates (PM2.1), which revealed that the protein phosphorylation level was increased significantly in cells after stimulation by fine particulate matters. The findings could provide a new insight for the nickel-based affinity protocol to analyze the mutation of phosphopeptides during cellular signaling pathways in response to exogenous environment stimulation. Consequently, this present work proposed a promising strategy to isolate monophosphopeptides from global phosphopeptides for phosphoproteome research.


Assuntos
Nanopartículas de Magnetita/química , Nanocompostos/química , Fosfopeptídeos/análise , Animais , Linhagem Celular , Humanos , Espectrometria de Massas , Leite/química , Níquel/química , Material Particulado/farmacologia , Fosfopeptídeos/sangue , Fosforilação/efeitos dos fármacos , Proteômica/métodos
4.
J Chromatogr A ; 1569: 168-177, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30077461

RESUMO

In this paper, a monolithic octadecylsilane column and particle-packed octadecylsilane columns were used to investigate the retention behaviors of oligonucleotides by ion-pair reversed-phase liquid chromatography (IP-RPLC). Results showed that, with same base composition, hairpin oligonucleotides always had weaker retention than corresponding random coil oligonucleotides on the monolithic column, but not on the particle-packed columns. In addition, the linear correlation between the retention factor k of oligonucleotides and the reciprocal of temperature (1/T), especially for hairpins, was relatively weaker on the particle-packed columns, as compared to the correlation on the monolithic column. The correlation between k and 1/T became weaker with decreasing particle size of the particle-packed columns. Moreover, results revealed that the overall retention order on the particle-packed column with small particles (3 µm) differed greatly from that on the monolithic column. In contrast, the retention order on the 10 µm particle-packed column was very close to that on the monolithic column. From the above, we inferred that oligonucleotides could keep their primary conformations unchanged when passing through the monolithic column, attributed to the special pore structures of the monolith. However, the conformations of oligonucleotides were suppressed or even destroyed when oligonucleotides passed through the particle-packed columns. This because the narrow and tortuous channels created by the stacked stationary phase particles could lead to more complex and unequable retention behaviors. Therefore, the monolithic column exhibited better retention regularity for oligonucleotides of secondary structure especially for hairpins than the particle-packed columns. It is noteworthy that the monolith-based IP-RPLC opens an intriguing prospect in accurately elucidating the retention behaviors of oligonucleotides.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Oligonucleotídeos/isolamento & purificação , Silanos/química , Íons , Temperatura
5.
J Chromatogr A ; 1542: 61-71, 2018 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-29475628

RESUMO

Polymorphism is inherent for G-quadruplexes (G4s), and the different structural forms are important for the participation in different biological functions of telomeres. A lot of progress has been made in the exploration of G4 polymorphism. However, quick separation and reliable assessment methods for different conformations of G4 are still very few. In this work, the polymorphism of three sequences d[(G3T)3G3], d[(G3C)3G3] and d[(G3T)4] annealed in six different solutions were investigated by means of reversed-phase high performance liquid chromatography (RP-HPLC), liquid chromatography-mass spectrometry (LC-MS), fluorescence spectroscopy, circular dichroism spectroscopy, together with native-polyacrylamide gel electrophoresis. Different G4 conformations of these three sequences can be separated clearly by RP-HPLC, and further characterized by on-line LC-MS analysis. It is revealed that high-order structures other than intramolecular quadruplexes were favored for d[(G3T)3G3] and d[(G3C)3G3] under the annealing conditions. However, flanking loop impeded d[(G3T)4] to form higher-order structures than dimer. In addition, the nature and concentration of cation, as well as the annealing solution component, all have decent influence on the stability and relative ratios of various G4 building blocks. Based on the above findings, RP-HPLC and LC-MS combined with spectroscopic techniques can be used as a facile and powerful tool for quick separation and identification of G4s in solutions, and for effective assessment of DNA sequences and annealing environments on G4 polymorphism. The established protocol provides a novel strategy for evaluating G4 polymorphism, which will facilitate studies on quadruplex structures and their biophysical properties.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Líquida , Cromatografia de Fase Reversa , Quadruplex G , Espectrometria de Massas em Tandem , Cátions/química , Espectrometria de Fluorescência
6.
J Sep Sci ; 39(23): 4502-4511, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27748038

RESUMO

The study on nucleic acid retention in ion-pair reversed-phase high-performance liquid chromatography mainly focuses on size-dependence, however, other factors influencing retention behaviors have not been comprehensively clarified up to date. In this present work, the retention behaviors of oligonucleotides and double-stranded DNAs were investigated on silica-based C18 stationary phase by ion-pair reversed-phase high-performance liquid chromatography. It is found that the retention of oligonucleotides was influenced by base composition and base sequence as well as size, and oligonucleotides prone to self-dimerization have weaker retention than those not prone to self-dimerization but with the same base composition. However, homo-oligonucleotides are suitable for the size-dependent separation as a special case of oligonucleotides. For double-stranded DNAs, the retention is also influenced by base composition and base sequence, as well as size. This may be attributed to the interaction of exposed bases in major or minor grooves with the hydrophobic alky chains of stationary phase. In addition, no specific influence of guanine and cytosine content was confirmed on retention of double-stranded DNAs. Notably, the space effect resulted from the stereostructure of nucleic acids also influences the retention behavior in ion-pair reversed-phase high-performance liquid chromatography.


Assuntos
Composição de Bases , Sequência de Bases , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Ácidos Nucleicos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...